Scanner & GS1 Data Matrix

Scanner & GS1 Data Matrix

Welcome to the NMVO Italia support page dedicated to scanner device configuration, aimed at ensuring correct operation within the national medicines verification system (NMVS).

With the introduction of the GS1 Data Matrix code and its coexistence with the current traceability system, it is essential to ensure that the scanner readers in use are correctly configured, updated, and fully compatible with the new 2D reading standards.

To support end users (pharmacies, wholesalers, and healthcare institutions), NMVO Italia actively collaborates with leading hardware manufacturers. This page gathers official instructions provided by participating vendors .

General Hardware Identification Guide 

Users are advised to identify the exact device model in use:

  • Label Identification: Each scanner has an identification label usually located on the base of the handle (for handheld models), on the bottom of the casing, or inside the battery compartment.

  • Required Information: The label displays the Brand (Manufacturer), the Model Name and the Part Number (P/N or product code). This information is essential to locate the correct configuration guide or firmware update on the manufacturer's website.

Partner Manufacturers and Useful Information  

Listed below are the partner manufacturers and useful information regarding devices that support GS1 Data Matrix scanning, as well as dedicated support channels.

Datalogic

  • QuickScan Family (handheld pistol scanner) 2500 and 2400
  • Gryphon Family (handheld pistol scanner) 4400, 4500 and 4600
  • Magellan (Presentation Mode)  900i, 1500, 3400, 3700
  • Magellan (in-counter installation) 3500, 3600
  • Eron Series 3400
  • RIDA handheld device

Zebra

  • DS82 Series: DS8208, DS8288 (Next Generation)
  • DS8100 Series: DS8108, DS8178
  • DS4600 Series: DS4608, DS4678
  • DS2200 Series: DS2208, DS2278
  • CS60 Series: CS6080
  • DS9900 Series: DS9908
  • DS9300 Series: DS9308
  • DS3600 Series: DS3608, DS3678

Obsolete / End of Life (EOL) Zebra Devices Compatible with GS1 Data Matrix 

  • DS6878 Series: DS6878-HC, DS6878-SR
  • DS6700 Series: DS6707, DS6708
  • DS4308 Series: DS4308-HC, DS4308-SR
  • DS9208 Series: DS9208
  • DS4208 Series: DS4208
  • CS4070 Series: CS4070, CS4070-HC
 
Honeywell (Brady) 

Institutional Notice and Disclaimer

Please note that the management, technical support, and configuration of reading devices, as well as their compatibility with the various software used by operators, fall outside the institutional scope and formal mandate entrusted to NMVO Italia.

As part of its support activities for the supply chain in achieving the required technological compliance, NMVO Italia provides this section for informational and guidance purposes only. For any technical further details, interoperability checks, or configuration procedures, please refer exclusively to your hardware supplier or software support representative.

Configurazione dei lettori scanner per l’accesso tramite GUI (Browser)

Attualmente, qualora ci si colleghi al sistema NMVS (National Medicines Verification System) tramite interfaccia web (GUI via browser), per garantire la conformità e la corretta trasmissione dei dati la pistola scanner deve essere configurata per includere un identificatore di simbologia all’inizio e un comando di invio alla fine della stringa GS1 catturata:

  • Prefisso (AIM ID): ]d2 (Standard globale che identifica un codice GS1 DataMatrix).

  • Suffisso: ENTER (Comando di ritorno a capo necessario per sottomettere automaticamente i dati nel form della pagina web).

Per applicare correttamente questi parametri al dispositivo:

  1. Verificare il modello della pistola scanner in dotazione.

  2. Contattare il proprio fornitore di fiducia o il servizio di assistenza dedicato fornendo le specifiche tecniche indicate sopra (Prefisso ]d2 e Suffisso ENTER).

⚠️ Nota Importante per gli Operatori Questa configurazione specifica per l’operatività tramite GUI browser dell’NMVS potrebbe interferire con la lettura del bollino farmaceutico all’interno del software gestionale aziendale. La formattazione avanzata dei codici (aggiunta di prefisso e suffisso) potrebbe alterare i dati trasmessi al gestionale, rendendo necessaria una verifica preventiva della compatibilità con il reparto IT o con il fornitore del software.